Skip to content
Skip to content

EX-HN10 Ju Quan () — Ju Quan — Gathered Spring

EX-HN10
Ju Quan
Ju Quan — Gathered Spring · Gathered Spring

In the oral cavity, on the midline at the center of the dorsal surface of the tongue

Anatomical illustration acupuntura.com · verified against Focks (2008), WHO/WPRO (2008), and Pontos e Meridianos

Extra PointWHO StandardDr. Hong Jin Pai — Livro de MeridianosSafeHead
Depth, Angle & Tissue Plane~3–5 mm
00.1–0.2 cun3.0
Perpendicular insertion
Anatomical precautions
Needle perpendicularly 0.1 to 0.2 cun, or perform bloodletting. Moxibustion is prohibited.

Anatomical location

In the oral cavity, at the midpoint of the median line, on the dorsal surface of the tongue. (Fig. 12.6)

Practical palpation guide

With the mouth open and the tongue extended, locate the point at the center of the median raphe on the dorsum of the tongue.

Needling technique

0.1 to 0.2 cun · perpendicular

Position along the channel pathwayExtra Points (WHO Standard)
Station 38 of 48
EX-HN10 · Ju QuanEX-HN138 / 48EX-HN15
Current pointFive-Shu / Yuan / Luo / Xi / Shu-MuOther channel stations

Medical application & myofascial correlation

Clinical practice indications

  • 01Altered tongue motility with motor aphasia
  • 02Difficulty discriminating tastes
  • 03Symptoms of diabetes and asthma

Presenting symptoms & complaints

Alteração de motilidade da língua com afasia motoraDificuldade para discriminar saboresSintomas de diabetes e asma

Classical tradition, channel actions & source

Traditional indications (TCM)

Altered tongue motility with motor aphasiaDifficulty discriminating tastesSymptoms of diabetes and asthma

Functional classification

Pontos Extras (EX)Cabeça e Pescoço (EX-CP)
Classical source:Zhen Jiu Da Cheng

Layered tissue anatomy & needle biomechanics at EX-HN10

Cross-sectional technical schematic of perpendicular insertion (90°) (0.1–0.2 cun): superficial connective collagen coupling, intramuscular myofascial transduction, and deep neurovascular protection.

Technical cross-section cutaway showing dermis and fascia, intramuscular spindle zone, and deep bone cortex and neurovascular bundle for EX-HN10.
1

Dermal & fascial collagen coupling

A solid non-cutting filiform needle (0.25 mm rounded tip) enters via perpendicular insertion (90°), gently tenting loose areolar collagen fibers without slicing dermal vessels.

2

Myofascial spindle & Aδ / C transduction

Within the 0.1–0.2 cun target window at EX-HN10, mechanical coupling recruits intramuscular mechanoreceptors, increasing local micro-perfusion and releasing taut bands.

3

Deep neurovascular clearance

Calibrated angle and depth keep the needle tip clear of periosteum and deep neurovascular trunks, pairing targeted stimulation with anatomical safety.

Original anatomical schematic · Physician review CEIMEC / acupuntura.comEX-HN10 · 0.1–0.2 cun

Translation and clinical dataProf. Dr. Hong Jin Pai — Meridians: Theory and Clinical Practice, 4th edition. CEIMEC · São Paulo.

CodingWHO Standard Acupuncture Point Locations (2008) for classical and extra points.