Skip to content
Skip to content

EX-UE9 Ba Xie () — Ba Xie — Eight Pathogens

EX-UE9
Ba Xie
Ba Xie — Eight Pathogens · Eight Evils

Four points on each hand, at the interdigital web margins between the 1st through 5th digits

Anatomical illustration acupuntura.com · verified against Focks (2008), WHO/WPRO (2008), and Pontos e Meridianos

Extra PointWHO StandardDr. Hong Jin Pai — Livro de MeridianosSafe
Depth & Angle
00.5–0.8 cun3.0
Oblique insertion

Anatomical location

Consists of four points on each hand. On the dorsum of the hand, at the transition between dark and light skin, near the margin of the interdigital web, between the fingers. (Fig. 12.15)

Practical palpation guide

With the fingers slightly flexed, locate the points at the margin of the interdigital web between the fingers, totaling four points on each hand.

Needling technique

0.5 to 0.8 cun · oblique

Position along the channel pathwayExtra Points (WHO Standard)
Station 36 of 48
EX-UE9 · Ba XieEX-HN136 / 48EX-HN15
Current pointFive-Shu / Yuan / Luo / Xi / Shu-MuOther channel stations

Medical application & myofascial correlation

Clinical practice indications

  • 01Headache
  • 02Sore throat
  • 03Toothache
  • 04High fever
  • 05Ophthalmalgia
  • 06Edema and pain on the dorsum of the hands
  • 07Numbness of the fingers and symptoms of malaria

Presenting symptoms & complaints

CefaléiaDor de gargantaDor de denteFebre altaOftalmalgiaEdema e dor no dorso das mãos

Classical tradition, channel actions & source

Traditional indications (TCM)

HeadacheSore throatToothacheHigh feverOphthalmalgiaEdema and pain on the dorsum of the handsNumbness of the fingers and symptoms of malaria

Functional classification

Pontos Extras (EX)Membro Superior (EX-MS)
Classical source:Zhen Jiu Da Cheng

Layered tissue anatomy & needle biomechanics at EX-UE9

Cross-sectional technical schematic of oblique insertion (~45°) (0.5–0.8 cun): superficial connective collagen coupling, intramuscular myofascial transduction, and deep neurovascular protection.

Technical cross-section cutaway showing dermis and fascia, intramuscular spindle zone, and deep bone cortex and neurovascular bundle for EX-UE9.
1

Dermal & fascial collagen coupling

A solid non-cutting filiform needle (0.25 mm rounded tip) enters via oblique insertion (~45°), gently tenting loose areolar collagen fibers without slicing dermal vessels.

2

Myofascial spindle & Aδ / C transduction

Within the 0.5–0.8 cun target window at EX-UE9, mechanical coupling recruits intramuscular mechanoreceptors, increasing local micro-perfusion and releasing taut bands.

3

Deep neurovascular clearance

Calibrated angle and depth keep the needle tip clear of periosteum and deep neurovascular trunks, pairing targeted stimulation with anatomical safety.

Original anatomical schematic · Physician review CEIMEC / acupuntura.comEX-UE9 · 0.5–0.8 cun

Translation and clinical dataProf. Dr. Hong Jin Pai — Meridians: Theory and Clinical Practice, 4th edition. CEIMEC · São Paulo.

CodingWHO Standard Acupuncture Point Locations (2008) for classical and extra points.